🧰 Installation Guide for Union Flexible Joints (Screw-End Rubber Expansion Joints)

By SYNTHETIC RUBBER PRODUCTS – The Largest Rubber Flexible Joint Supplier in Malaysia

The Highest Quality Union Flexible Joint Manufacturer

Union Flexible Joints, also known as Screw-End Rubber Expansion Joints, are precision-engineered components used in pipelines to absorb vibration, reduce stress, and compensate for thermal movement.
Proper installation is crucial to ensure maximum performanceleak-free sealing, and long service life.

 

βš™οΈ Pre-Installation Preparation

Before starting installation in any piping system — whether in Kuala LumpurPenangJohor BahruKota Kinabalu, or Kuching — carefully inspect the components and site conditions.

βœ… 1. Verify Product and Site Conditions

  • Confirm the modelsize, and material type (EPDM, Neoprene, or NBR) according to your system requirements.
  • Ensure the pipe ends and union threads match correctly (BSP or NPT type).
  • Check that the rubber bellows are not twisted, cracked, or deformed.
  • Verify pressure and temperature ratings against actual system conditions.
    (Example: standard pressure rating PN16 up to 16 bar; temperature up to 120°C depending on rubber material.)

βœ… 2. Prepare Tools and Accessories

You’ll need:

  • Adjustable spanners or pipe wrenches
  • PTFE thread seal tape or sealing compound (for threaded unions)
  • Pipe alignment tool or level gauge
  • Lubricant (non-petroleum-based, for rubber protection)
  • Pressure gauge for system testing

 

πŸ”© Installation Steps

🧱 Step 1: Check Pipe Alignment

  • Ensure both pipeline ends are aligned and level before installation.
  • Misalignment will stress the rubber bellows and shorten its lifespan.
  • Use a spirit level or alignment jig to verify straightness.

🧱 Step 2: Clean the Connection Ends

  • Clean both pipe threads and union ends thoroughly.
  • Remove dirt, rust, and debris to avoid leaks.

🧱 Step 3: Apply Thread Sealant

  • Wrap PTFE tape around the male threads in a clockwise direction (3–4 turns).
  • Alternatively, apply an approved liquid thread sealant compatible with water, oil, or chemical service.
  • Avoid excess sealant entering the rubber bellows.

🧱 Step 4: Install the Union Flexible Joint

  • Hold the flexible joint in neutral position (not stretched or compressed).
  • Align it between the two threaded pipe ends.
  • Hand-tighten both union nuts first.
  • Then use a wrench to tighten securely — typically 1/2 to 1 full turn after hand-tight.
    ⚠️ Do not over-tighten — excessive torque may damage threads or compress the bellows excessively.

🧱 Step 5: Check Alignment and Neutral Position

  • After tightening, ensure the rubber body is not twisted or bent.
  • The joint must remain in a neutral position at system’s normal temperature.
  • There should be a slight gap between the bellows and metal ends to allow movement.

🧱 Step 6: Pressure Test

  • Slowly pressurize the system to half working pressure and check for leaks.
  • If no leakage, raise to full working pressure.
  • Observe for any deformation or movement in the bellows.
    If leakage occurs, depressurize, reseal threads, and retighten unions.

 

πŸ”§ Installation Tips for Best Performance

βœ… Always install in neutral condition — do not pre-compress or pre-stretch.
βœ… Support pipelines properly with hangers or anchors; the joint is not a load-bearing element.
βœ… Leave sufficient space around the joint for thermal movement and maintenance.
βœ… Never use the joint to correct pipe misalignment — use alignment fittings first.
βœ… For vertical installations, support the weight of the piping with clamps to avoid overloading the joint.
βœ… Avoid direct exposure to UV sunlight or ozone — shield with protective covers if outdoors.
βœ… Do not paint or coat the rubber body.

 

πŸ§ͺ Post-Installation Testing and Maintenance

πŸ” Initial Inspection

  • After system pressurization, check for:
    • Leaks at threads or unions
    • Excessive bulging of rubber bellows
    • Unusual vibration or noise

πŸ” Routine Maintenance (Every 6–12 Months)

  • Inspect rubber for aging, cracking, or deformation.
  • Ensure union connections are tight and leak-free.
  • Clean external surfaces to remove oil or dust.
  • Rotate or replace joints if used in high-vibration environments (e.g., pumps or compressors).

🧯 Replacement Indicators

Replace the joint if:

  • Cracks appear on the bellows
  • Leaks persist even after tightening
  • Swelling or deformation exceeds 10% of original shape
  • The rubber becomes brittle due to temperature or chemical exposure

 

πŸ—οΈ Installation Locations Across Malaysia

Our Union Flexible Joints are installed nationwide — across:

  • Peninsular Malaysia: Kuala Lumpur, Selangor, Johor Bahru, Penang, Ipoh, Seremban, Melaka, Kuantan, Alor Setar, Kota Bharu, Kuala Terengganu, Kangar.
  • East Malaysia: Kota Kinabalu, Sandakan, Tawau, Lahad Datu, Keningau, Kuching, Miri, Bintulu, Sibu, Limbang, and beyond.

Engineers and contractors across Malaysia trust SYNTHETIC RUBBER PRODUCTS for vibration isolationnoise reduction, and long-lasting performance in mechanical, plumbing, and marine installations.

 

πŸ† Why Choose SYNTHETIC RUBBER PRODUCTS

βœ… The Largest Rubber Flexible Joint Supplier in Malaysia
βœ… The Highest Quality Union Flexible Joint Manufacturer
βœ… Designed for easy installationlong lifespan, and leak-free operation
βœ… Backed by nationwide technical support and ISO-certified production standards
βœ… Trusted by industries from HVACplumbingmarinechemical, to public infrastructure

 


View more about Rubber Joint Penang | Rubber Expansion Joint Johor Bahru | Flexible Rubber Joint Melaka | Rubber Expansion Joint Negeri Sembilan | Rubber Flexible Joint Pahang on main site